Home Up SS Wood SS Steel Sheetrock Hurricane Ceiling Screws Pole Tool Sammy Assortment Sammy Saddle Sammy Xpress Sammy Swivel Head Dektite Install Kit GST - Wood Sammy SWG - Wood SW DST - Steel Sammy SWDR - Steel SW CST - Concrete Sammy SWC - Concrete SW

All-thread Rod Anchoring Systems


Steel Sammy - Self drilling & self-tapping into steel   

 


Steel ¼" Rod Vertical Mount
#14
Item #100

PN 8113910

Use #14 Nut Driver (Item #100)
Item # Part # Model Rod Size Description
50 8024957 DSTR 100¹ ¼ - 20 ¼ - 20 x 1
51 8025957 DST 100 ¼ - 20 ¼ - 14 x 1
52 8026957 DST 150 ¼ - 20 ¼ - 14 x 1½
53 8027957 DST 200 ¼ - 20 ¼ - 14 x 2
56 8030957 TEK 500 ¼ - 20 12 - 24 x 1½
¹ When installing DSTR or SWDR add retainer nut and torque to 20 foot lbs. for maximum pull out in steel.

 

Steel 3/8" Rod Vertical Mount
Use #14 Nut Driver (Item #100)
  Item
No
Part # Model Rod
Size
Description UL
Test
Load
(lb)
UL Minimum Steel Thickness inches FM
Test
Load
(lb)
FM Minimum Steel Thickness inches UL/FM Pipe Size inches Minimum
Thickness
Max.
Thick.
Actual
Pullout
29 8037957 DSTR 1½" 3/8-16 12-24x1½ 1500 .035 1475 .105 4/4 .036"-20ga .188 1510# / 20ga
30 8038957 DSTR 1" 3/8-16 ¼-20x1 1500 .035 1475 .105 4/4 .036"-20ga .188 1510# / 20ga
31 8039957 DSTR 516 3/8-16 5/16-18x1¼  1500 .037 1475 .105 4/4 .036"-20ga .188 2200# / 20ga
  32 8040957 DST 10 3/8-16 ¼-14x1           .036"-20ga .188 446# / 20ga
  33 8041957 DST 15 3/8-16 ¼-14x1½           .066"-16ga .188 970# / 16ga
  34 8042957 DST 20 3/8-16 ¼-14x2 Note: Screw diameter/design/performance for DST 10
(1” length) through DST 30 (3” length) are constant.
Only the lengths vary.
  35 8043957 DST 25 3/8-16 ¼-14x2½
  36 8044957 DST 30 3/8-16 ¼-14x3
37 8045957 DST 516 3/8-16 5/16-18x1¼ 1500 .188 1475 .188 4/4 .188"-3/16" .188 1500+# / 3/16"
38 8046957 TEK 50 3/8-16 12-24x1½ 1500 .250 1475 .188 4/4 .25"-¼" .500 3125# / ¼"
#14
Item #100

PN 8113910

²  When installing DSTR or SWDR add retainer nut and torque to 20 foot lbs. for maximum pull out in steel.
 

Click on symbol to link direct to UL Online Certification

Click on symbol to link direct to FM Global Loss Prevention Data Sheet 1-2.

Steel ½" Rod Vertical Mount
#14SW
Item #101

PN  8114910

Note: #14SW must be used
 for screws with
½" cap.

Use #14SW Nut Driver (Item #101)
Item
No
Part # Model Rod
Size
Screw
Description
Minimum
Thickness
Maximum
Thickness
Actual
Pullout
601 8031925 DST 2.0 ½ - 13 ¼ - 14 x 2 .188" - 3/16" 1/4"  
422 8033925 DSTR 1.0 ½ - 13 ¼ - 20 x 1 .036" - 20 ga 1/4" 1510# / 20 ga
28 8034925 DSTR 5.16 ½ - 13 5/16 - 18 x 1¼ .036" - 20 ga 1/4" 2220# / 20ga
443 8035925 DST 5.16 ½ - 13 5/16 - 18 x 1¼ .188" - 3/16" 1/4"  1500+# / 3/16"
05 8036925 TEK 5.0 ½ - 13 12 - 24 x 1½ .250" - ¼" 1/2" 3125# / ¼"

 

    Legend
Factory Mutal Approved
UL-listed.
Box quantity 25. Standard box quantity 125, except where so indicated.

Factory Mutual and UL listed approvals - pdf

Link to DOWNLOADS including:   Product Catalog, engineering (CAD) drawings, list of FM approvals,  ICC Evaluation Service, Miami Dade Online Certification and UL test reports.

VERTICAL MOUNT.pdf


Installation Diagrams

All installations must be performed with appropriate nut driver to comply with warranty.

 

Installation Instructions

Installation Instructions
DST, DSTR, TEK 50, SWD, SWDR, SWT
See Figures 1 through 4 (vertical) and 11 through 14 (horizontal) of detailed installation instructions for illustrations.
  •  DST self-drills & self-taps into steel up to 3/16" thick.
  • DSTR self-drills & self-taps into steel up to 3/16" thick and accepts retainer nut.
  • TEK 50 - Self-drills & self- taps into steel up to ½" thick.
  • SWD self-drills & self-taps through 3/16" steel.
  • SWDR self-drills & self-taps through 3/16" steel and accepts retainer nut.
  • SWT self-drills & self-taps through ½" steel.
Step 1: Insert the appropriate nut driver into a 3/8" or ½" portable drill:
  1. use #14 Nut Driver for DST, DSTR, TEK 50;
  2. use #14SW Nut Driver for SWD, SWDR, SWT.

Step 2: Insert the screw into the nut driver. Now you are ready to install the screw.

Step 3: Position drill and begin installation:

  1. for installing DST, TEK 50, DSTR*, the drill should be in a vertical position;
  2. for installing SWD, SWDR*, SWT, the drill should be in a horizontal position at a right angle to the structural member.

Step 4: When the nut driver spins freely on the cap of the screw installation is complete.

Step 5: Screw is now ready to receive ¼", 3/8", ½" or metric all-thread rod or bolt stock.


Download CAD Drawings Installation Instructions Safety Information Performance Data

Home SS Wood SS Steel Sheetrock Hurricane Ceiling Screws Pole Tool Sammy Assortment Sammy Saddle Sammy Xpress Sammy Swivel Head Dektite Install Kit GST - Wood Sammy SWG - Wood SW DST - Steel Sammy SWDR - Steel SW CST - Concrete Sammy SWC - Concrete SW

Information: submit a request or contact, marketing@itwbuildex.com

Last modified: August 26, 2008         -   An independent, non-profit content rating organization.

Copyright © 2002-2008:   ITW Buildex. All trademarks or registered trademarks used are trademarks of Sammy Super Screw
®, ITW Buildex and Illinois Tool Works, Inc.   ITW Buildex Privacy Policy

ITW Buildex uses WebTrends Live to analyze traffic to this web site.  WebTrends Live does not create individual profiles for visitors.  Unlike some tracking services WebTrends Live does not have a database of individual profiles for each visitor.  WebTrends Live only collects aggregate data.  For more information about WebTrends Live privacy policy, please click here.

Send mail to: webmaster@itwbuildex.com  with questions or comments about the webpage.